中文 | English  

PRODUCT

Location: Home> Products Drop in Circulator

Drop in Circulator

Description :

The HTD 504 series Circulator offers high performance

at very competitive pricing.This rugged design uses a screwed in

lid,and machined housing.Devices are fully tested to handle

shock,vibration,thermal shock and moisture,making them

suitable of base station and other infrastructure environments


Features:

Low Insertion Loss 0.15dB

High Isolation 28dB

Customization available

Fully RoHS Compliant


Absolute Maximum Ratings

Parameter

Absolute Maximum

Peak Power

500 Watts

Forward Power

100 Watts

Reverse Power

100W

Standard Operating Temperature

-40- +100

Storage Temperature

-40- +120


Electrical Specifications

Parameter

Units

Typical

25℃

Typical

-40℃-85℃

Typical

-40℃- +100℃

Insertion Loss

dB

0.15

0.2

0.25

Isolation

dB

28

26

23

Return Loss(Port1&2)

dB

26

24

21

IMD(2×30W,5MHZ separation)

dBc

-72

-65

-60